11
Code/State Modification?
[
YES = continue, ESC/NO = skip]
Tran. State Modification
Lets you change the control panel default settings for
how and/or whether certain conditions are reported to
the central station. There are three possible settings
for each state:
Alarmalarm reports only
Alarm/Endalarm and restore reports
No Trans
—no report
There are 15 states described below
with their default setting that can be changed.
>
DEVICEAlarm
>
ALERT Alarm
>
INITIALIZATION —No Trans
>
PANEL BATTERIES—No Trans
>
AC POWER—No Trans
>
PHONE LINE FAULT—No Trans
>
TAMPERAlarm/End
>
DEVICE BATT.—No Trans
>
RADIO JAMMING—No Trans
>
SUPERVISION—No Trans
>
PERIODIC TESTAlarm
>
WRONG CODES—No Trans
>
DURESS CODE—No Trans
>
ALARM MEMORY—No Trans
>
ARM/DISARM—No Trans
1. With the display showing TRANS. STATE MODIFICATION:
press
Yes. The display shows the rst state/setting
DETECTOR ALARM.
2.
Press YES to change this setting or press either arrow
button until the desired state/setting is displayed, then
press
YES. A colon (:) appears indicating that you may
now change the current setting.
3.
Press either arrow button until the desired setting
appears, then press YES. The colon disappears and the
the new setting is displayed.
4. Repeat steps 2 and 3 for all other setting changes.
5.
When all desired changes are done, press ESC/NO.
The display returns to TRANS. STATE MODIFICATION.
6. Press the right arrow button once. The display shows
ALARM CODE MODIFICATION.
Alarm Code Modification
Lets you change the default alarm reporting code of
each system device.
Note: Although this menu appears at this point in the
cycle, pressing YES produces the display message NO
EQUIPMENTS RECORDED. After devices (equipment)
and all initial system programming are programmed
(recorded) into control panel memory, you must start
a new programming session to modify these codes.
System Code Modification
Lets you change the system codes the control panel
reports to the central station. There are 16 codes
described below with their default settings that can
be changed.
>
ALERT—code 120
>
INITIALIZATION—code 305
>
BATTERY FAULT—code 302
>
BATTERY RESTORE—code 302
>
AC POWER—code 301
>
PHONE LINE FAULT—code 351
>
TAMPER—code 383
>
DEVICE BATTERY—code 384
>
RADIO JAMMING—code 344
>
SUPERVISION—code 355
>
PERIODIC TEST—code 602
>
WRONG CODES—code 461
>
DURESS CODE—code 121
>
ALARM MEMORY—code 624
>
ARMING—code 400
>
DISARMING—code 400
1. With the display showing ALARM CODE MODIFICATION,
press the right arrow button once. The display shows
SYSTEM CODE MODIFICATION.
2.
Press YES. The display shows ALERT CODE 120
3.
Press either arrow button until the desired system
code is displayed, then press
YES. A colon (:) appears
indicating that you may now change the current setting.
4.
Enter the desired 3-digit code, then press YES.
The colon disappears and the new setting is displayed.
5.
Repeat steps 3 and 4 for all other setting changes.
6.
When all desired changes are done, press ESC/NO.
The display returns to SYSTEM CODE MODIFICATION.
Initial Configuration/Programming
Installation Sequence